[beta] Set an equipment digital output state
Set the state of a digital output on the gateway connected to a piece of powered equipment. The command is delivered to the device synchronously; a success response indicates the device acknowledged and applied the requested state. This requires an AG53 gateway connected to powered equipment via the CBL-AG-BEQP cable.
<b>Rate limit:</b> 100 requests/min (learn more about rate limits <a href="https://developers.samsara.com/docs/rate-limits" target="_blank">here</a>).
To use this endpoint, select Write Equipment Output Control under the Closed Beta category when creating or editing an API token. <a href="https://developers.samsara.com/docs/authentication#scopes-for-api-tokens" target="_blank">Learn More.</a>
Submit Feedback: Likes, dislikes, and API feature requests should be filed as feedback in our <a href="https://forms.gle/zkD4NCH7HjKb7mm69" target="_blank">API feedback form</a>. If you encountered an issue or noticed inaccuracies in the API documentation, please <a href="https://www.samsara.com/help" target="_blank">submit a case</a> to our support team.
Request
- Base URLhttps://api.samsara.com
- AuthHTTP bearer
Path parameters
The Samsara ID of the gateway whose digital output is being controlled. This must be an AG53 connected to powered equipment via the CBL-AG-BEQP cable.
Request body
Example request
{
"durationSeconds": 60,
"pinId": 1,
"state": true
}Response
OK response.
Example response
{
"data": {
"durationSeconds": 60,
"id": 1234,
"pinId": 1,
"state": true
}
}Changes