Integrations
NVSentinel node faults ↔ optical state of the node's uplink (±60 s)
For every NVSentinel health event in the window (default categories: GPU driver unresponsive, mlx5 NIC wedge, IB char-device missing, power brake; categories=all for everything) look at the node's switch uplink: optical_readings ±60 s (rx power / temperature / FEC) and risk_alerts. sync=true first pulls new rows from the NVSentinel PostgreSQL store when FIBER_NVSENTINEL_PG_DSN is set.
get/api/integrations/nvsentinel/correlation
Request
- Base URL: https://api.fiber.ac (the document declares no server; this is the origin it was published from)
- URL: https://api.fiber.ac/api/integrations/nvsentinel/correlation
- Auth: none declared
Query parameters
minutesinteger
categoriesstring
comma list or 'all'; default = the four target categories
include_healthyboolean
syncboolean
poll the NVSentinel PostgreSQL store first (if configured)
Response
Successful Response
unknown required
Changes
No recorded changes to this operation across all 1 revision of this API.