Sensors
Set the count zone of a waffle sensor and send it with a SET_ZONE command.
The zone is normalized to the canonical WKT the sensor reports back. It's sent
even when unchanged, which recovers a command the sensor missed.
Example JSON request body:
`{"zone": "POLYGON ((-2.5 0.5, 2.5 0.5, 2.5 6, -2.5 6, -2.5 0.5))"}`
put/v2/sensors/{serial_number}/config/zone/
Request
- Base URL: https://api.density.io
- URL: https://api.density.io/v2/sensors/{serial_number}/config/zone/
- Auth: API key in header Authorization
Request body
Response
Updated
Changes
- info
endpoint added
- info