Heart v2 - Get
Provides the high frequency data of an ECG recording in micro-volt (μV).
Duration:
- BPM Core: 20 seconds.
- Move ECG: 30 seconds.
- ScanWatch: 30 seconds.
Sampling frequency:
- BPM Core: 500 Hz.
- Move ECG: 300 Hz.
- ScanWatch: 300 Hz.
Request
- Base URLhttps://wbsapi.withings.net
- Authnone declared. Required headers: Authorization
Query parameters
Service action name. Must take the string value get.
DO NOT USE WITH FOLLOWING PARAMS: [client_id, signature, nonce, signal_token]<br>ID of a signal
DO NOT USE WITH FOLLOWING PARAMS: [access_token, signalid]<br>Id of the client
DO NOT USE WITH FOLLOWING PARAMS: [access_token, signalid]<br>Hash of params (Cf. Signature hash protocol).
DO NOT USE WITH FOLLOWING PARAMS: [access_token, signalid]<br>A random token used to prevent replay attacks (Cf. Signature v2 - Getnonce)
DO NOT USE WITH FOLLOWING PARAMS: [access_token, signalid]<br>Signal identifier
Request filtered version of the signal
Request features with inactive ones
Headers
Used to pass your access token. Must take value: Bearer {your access_token} Replace {your access_token} with the access_token
Response
(Click to unfold)
Example response
{
"body": {
"sampling_frequency": 500,
"wearposition": 1,
"model": 44,
"heart_rate": {
"grpid": 5586822735,
"value": 82,
"date": 1717530817
}
}
}Changes
No recorded changes to this operation across all 1 revision of this API.