Monitors

Get a project monitor

Returns a single project monitor. Requires monitors:read. An existing container_cpu monitor without an effective CPU limit remains visible with evaluation_unavailable_reason set to cpu_limit_missing.

get/v1/projects/{projectId}/monitors/{alertId}

Request

  • Base URL
    https://api.spice.ai
  • Auth
    HTTP bearer

Path parameters

projectIdinteger required
alertIdstring uuid required

Headers

X-Org-Namestring

The organization to act on, by handle. Omit it to act on the organization the credential is bound to; sending it blank is a 400, not the same as omitting it. A user credential may name any organization its owner belongs to; a machine credential is pinned to its own. A portal session token is bound to none, so it must send this header on every route but GET /v1/orgs (400 org_assertion_required otherwise).

Response

Monitor

idstring uuid required

Identifier of the monitor or reaction. This is the value the get, update and delete operations take.

org_idinteger required

Organization that owns the project

app_idinteger required

Project the monitor or reaction belongs to

created_byinteger nullable required

User who created it, when it was created by a user credential

namestring required

Display name, unique case-insensitively among the project's live monitors and data reactions

descriptionstring nullable required
kind'runtime' required

The monitors endpoints only ever return runtime.

status'active' | 'disabled' required

Whether it is evaluating

template_idstring required

Template it was created from

specobject required

Monitor parameters. Which properties are meaningful is decided by template_id. The create operation's request body lists the properties each template reads.

recipient_user_idsinteger[] required

Organization members emailed when the monitor fires. Empty when there is no email sink, and for an email sink addressed only by emails. When a created email sink named no recipients at all, the API stores the creating user; a machine credential has no user, so it stores none and the monitor emails the organization owner.

last_fired_atstring date-time nullable required

When it last fired, or null if it never has

last_resolved_atstring date-time nullable required

When it last resolved, or null if it never has

created_atstring date-time required
updated_atstring date-time required
evaluation_unavailable_reason'cpu_limit_missing'

Present when an existing Instance CPU monitor cannot evaluate because its CPU limit was removed.