PicoLoadmanagementSetDynamicCurrent
Sets the three-phase dynamic current for a load management group.
post/pico/loadmanagementgroup/threephasecurrent/{id}
Request
- Base URL: https://api.smart-me.com (the document declares no server; this is the origin it was published from)
- URL: https://api.smart-me.com/pico/loadmanagementgroup/threephasecurrent/{id}
- Auth: one of:
- OAuth 2 (authorization code, authorization URL /oauth/authorize, token URL /oauth/token; client credentials, token URL /oauth/token)
- HTTP basic
Path parameters
idstring uuid required
The load management group id
Query parameters
PhaseL1integer required
Represents the current for Phase L1 in milliamperes (mA). Acceptable values are 0 mA or between 6000 and 6’400’000 mA (inclusive). All values must be multiples of 1000.
PhaseL2integer required
Represents the current for Phase L1 in milliamperes (mA). Acceptable values are 0 mA or between 6000 and 6’400’000 mA (inclusive). All values must be multiples of 1000.
PhaseL3integer required
Represents the current for Phase L1 in milliamperes (mA). Acceptable values are 0 mA or between 6000 and 6’400’000 mA (inclusive). All values must be multiples of 1000.
Response
The three-phase dynamic current was successfully set
Changes
No recorded changes to this operation across all 1 revision of this API.