PicoLoadmanagementSetDynamicCurrent

Sets the three-phase dynamic current for a load management group.

post/pico/loadmanagementgroup/threephasecurrent/{id}

Request

  • Base URL: https://api.smart-me.com (the document declares no server; this is the origin it was published from)
  • URL: https://api.smart-me.com/pico/loadmanagementgroup/threephasecurrent/{id}
  • Auth: one of:
    • OAuth 2 (authorization code, authorization URL /oauth/authorize, token URL /oauth/token; client credentials, token URL /oauth/token)
    • HTTP basic

Path parameters

idstring uuid required

The load management group id

Query parameters

PhaseL1integer required

Represents the current for Phase L1 in milliamperes (mA). Acceptable values are 0 mA or between 6000 and 6’400’000 mA (inclusive). All values must be multiples of 1000.

PhaseL2integer required

Represents the current for Phase L1 in milliamperes (mA). Acceptable values are 0 mA or between 6000 and 6’400’000 mA (inclusive). All values must be multiples of 1000.

PhaseL3integer required

Represents the current for Phase L1 in milliamperes (mA). Acceptable values are 0 mA or between 6000 and 6’400’000 mA (inclusive). All values must be multiples of 1000.

Response

The three-phase dynamic current was successfully set

Changes

No recorded changes to this operation across all 1 revision of this API.