PicoLoadmanagementGroup

get/pico/loadmanagementgroup/{id}

Request

  • Base URL: https://api.smart-me.com (the document declares no server; this is the origin it was published from)
  • URL: https://api.smart-me.com/pico/loadmanagementgroup/{id}
  • Auth: one of:
    • OAuth 2 (authorization code, authorization URL /oauth/authorize, token URL /oauth/token; client credentials, token URL /oauth/token)
    • HTTP basic

Path parameters

idstring uuid required

Response

OK

namestring nullable required

Name of the load management group

maxCurrentnumber double required

Maximum current limit of the fuse in amperes

connectionLostActionType0 | 1 | 2 required
<p>Members: </p><ul><li><i>0</i> - NoAction</li><li><i>1</i> - MinCurrent</li><li><i>2</i> - DynamicCurrent</li></ul>
connectionLostDynamicCurrentnumber double required

Dynamic current limit in amperes to apply when connection is lost

changeFrom3PhaseTo1PhaseCurrentInAinteger required

Current threshold in amperes for switching from 3-phase to 1-phase charging

enable1To3PhaseChangeboolean required

Enable automatic switching between 1-phase and 3-phase charging

max1PhaseChargingCurrentInAinteger required

Maximum charging current in amperes allowed during 1-phase charging

idstring uuid required

Unique identifier of the load management group

numberOfStationsinteger required

Number of charging stations in the load management group

Changes

No recorded changes to this operation across all 1 revision of this API.