isEnabledboolean
Flag if the device is enabled. Disabled devices don't receive new values.
deviceEnergyType0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13
<p>Members: </p><ul><li><i>0</i> - MeterTypeUnknown</li><li><i>1</i> - MeterTypeElectricity</li><li><i>2</i> - MeterTypeWater</li><li><i>3</i> - MeterTypeGas</li><li><i>4</i> - MeterTypeHeat</li><li><i>5</i> - MeterTypeHCA</li><li><i>6</i> - MeterTypeAllMeters</li><li><i>7</i> - MeterTypeTemperature</li><li><i>8</i> - MeterTypeMBusGateway</li><li><i>9</i> - MeterTypeRS485Gateway</li><li><i>10</i> - MeterTypeCustomDevice</li><li><i>11</i> - MeterTypeCompressedAir</li><li><i>12</i> - MeterTypeSolarLog</li><li><i>13</i> - MeterTypeVirtualMeter</li></ul>
meterSubType0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9
<p>Members: </p><ul><li><i>0</i> - MeterSubTypeUnknown</li><li><i>1</i> - Cold / Cold Water Meter</li><li><i>2</i> - Heat / Hot Water Meter</li><li><i>3</i> - MeterSubTypeChargingStation</li><li><i>4</i> - MeterSubTypeElectricity</li><li><i>5</i> - MeterSubTypeWater</li><li><i>6</i> - MeterSubTypeGas</li><li><i>7</i> - Electricity / Heat meter</li><li><i>8</i> - A Temperature meter</li><li><i>9</i> - MeterSubTypeVirtualBattery</li></ul>
familyType0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 14 | 16 | 17 | 18 | 19 | 21 | 65 | 70 | 1001 | 1002 | 1003
The Family Type of the meter (e.g. Smart-me connect meter)<p>Members: </p><ul><li><i>0</i> - The Family Type is unknown (S0 meters, ...)</li><li><i>1</i> - smart-me connect Meter (Plugin Power Meter)</li><li><i>2</i> - smart-me Meter (1-Phase DIN Rail Meter) without switch</li><li><i>3</i> - smart-me Meter (1-Phase DIN Rail Meter) with a Switch</li><li><i>4</i> - smart-me M-BUS Gateway V1</li><li><i>5</i> - Reserved for the retired smart-me RS-485 Gateway V1</li><li><i>6</i> - MeterFamilyTypeKamstrupModule</li><li><i>7</i> - MeterFamilyTypeSmartMe3PhaseMeter80A</li><li><i>8</i> - smart-me 3-Phase Meter 32A (with Switch)</li><li><i>9</i> - smart-me 3-Phase Meter Transformer Edition</li><li><i>10</i> - smart-me Landis Gyr Module</li><li><i>11</i> - Optical module for the FNN meters</li><li><i>12</i> - smart-me 3-Phase Meter 80A with the new WiFi (V2)</li><li><i>14</i> - smart-me 3-Phase Meter 80A with Mobile</li><li><i>16</i> - smart-me 1-Phase Meter 80A with the new WiFi (V2)</li><li><i>17</i> - smart-me 1-Phase Meter 32A with the new WiFi (V2)</li><li><i>18</i> - smart-me 1-Phase Meter 80A with GPRS</li><li><i>19</i> - smart-me 1-Phase Meter 32A with GPRS</li><li><i>21</i> - smart-me 3-Phase Meter Transformer Edition with mobile module</li><li><i>65</i> - smart-me 3-phase Meter Nimbus (3-point meter)</li><li><i>70</i> - Mithral hall charging station Version 1</li><li><i>1001</i> - REST API Meter</li><li><i>1002</i> - Virtual billing Meter (e.g. for smart-me washroom)</li><li><i>1003</i> - M-BUS Meter read out by a smart-me M-BUS Gateway</li></ul>
activePowernumber double nullable
The Actvie Power or current flow rate
activePowerL1number double nullable
The Actvie Power Phase L1
activePowerL2number double nullable
The Actvie Power Phase L2
activePowerL3number double nullable
The Actvie Power Phase L3
activePowerUnitstring nullable
The Unit of the Active Power Value
counterReadingnumber double nullable
The Meter Counter Reading (Total Energy used)
counterReadingUnitstring nullable
The Unit of the Counter Reading
counterReadingT1number double nullable
The Meter Counter Reading Tariff 1
counterReadingT2number double nullable
The Meter Counter Reading Tariff 2
counterReadingT3number double nullable
The Meter Counter Reading Tariff 3
counterReadingT4number double nullable
The Meter Counter Reading Tariff 4
counterReadingImportnumber double nullable
The Meter Counter Reading only import
counterReadingExportnumber double nullable
The Meter Counter Reading only export
switchOnboolean nullable
Flag if the Switch is on on this device.
switchPhaseL1Onboolean nullable
Flag if the Phase L1 is on on this device.
switchPhaseL2Onboolean nullable
Flag if the Phase L2 is on on this device.
switchPhaseL3Onboolean nullable
Flag if the Phase L3 is on on this device.
voltagenumber double nullable
voltageL1number double nullable
The Voltage Phase L1 (in V)
voltageL2number double nullable
The Voltage Phase L2 (in V)
voltageL3number double nullable
The Voltage Phase L3 (in V)
currentnumber double nullable
currentL1number double nullable
The Current Phase L1 (in A)
currentL2number double nullable
The Current Phase L2 (in A)
currentL3number double nullable
The Current Phase L3 (in A)
powerFactornumber double nullable
The Power Factor (cos phi). Range: 0 - 1
powerFactorL1number double nullable
The Power Factor (cos phi) Phase L1. Range: 0 - 1
powerFactorL2number double nullable
The Power Factor (cos phi) Phase L2. Range: 0 - 1
powerFactorL3number double nullable
The Power Factor (cos phi) Phase L3. Range: 0 - 1
temperaturenumber double nullable
The Temperature (in degree celsius)
activeTariffinteger nullable
The Number of the Active Tariff
digitalOutput1boolean nullable
The digital output number 1
digitalOutput2boolean nullable
The digital output number 2
analogOutput1integer nullable
The analog output number 1 (PWM signal) (0 - 32183)
analogOutput2integer nullable
The analog output number 2 (PWM signal) (0 - 32183)
digitalInput1boolean nullable
The digital input number 1
digitalInput2boolean nullable
The digital input number 2
valueDatestring date-time nullable
Time of last successful connection the the smart-me Cloud.
additionalMeterSerialNumberstring nullable
An additional Meter serial number. e.g. the number of a meter a smart-me device is connected to.
flowRatenumber double nullable
The current flow rate (e.g. m3/h)
chargingStationState0 | 1 | 2 | 3 | 4 | 5 | 6 | 7
State of a (pico) charging station<p>Members: </p><ul><li><i>0</i> - Booting</li><li><i>1</i> - ReadyNoCarConnected</li><li><i>2</i> - ReadyCarConnected</li><li><i>3</i> - StartedWaitForCar</li><li><i>4</i> - Charging</li><li><i>5</i> - Installation</li><li><i>6</i> - Authorize</li><li><i>7</i> - Offline</li></ul>