Gets all Devices
Gets all Devices
Request
- Base URL: https://api.smart-me.com (the document declares no server; this is the origin it was published from)
- URL: https://api.smart-me.com/Devices
- Auth: one of:
- OAuth 2 (authorization code, authorization URL /oauth/authorize, token URL /oauth/token; client credentials, token URL /oauth/token)
- HTTP basic
Response
OK
The ID of the device
The Name of the Device
The Serial number
Flag if the device is enabled. Disabled devices don't receive new values.
The Family Type of the meter (e.g. Smart-me connect meter)<p>Members: </p><ul><li><i>0</i> - The Family Type is unknown (S0 meters, ...)</li><li><i>1</i> - smart-me connect Meter (Plugin Power Meter)</li><li><i>2</i> - smart-me Meter (1-Phase DIN Rail Meter) without switch</li><li><i>3</i> - smart-me Meter (1-Phase DIN Rail Meter) with a Switch</li><li><i>4</i> - smart-me M-BUS Gateway V1</li><li><i>5</i> - Reserved for the retired smart-me RS-485 Gateway V1</li><li><i>6</i> - MeterFamilyTypeKamstrupModule</li><li><i>7</i> - MeterFamilyTypeSmartMe3PhaseMeter80A</li><li><i>8</i> - smart-me 3-Phase Meter 32A (with Switch)</li><li><i>9</i> - smart-me 3-Phase Meter Transformer Edition</li><li><i>10</i> - smart-me Landis Gyr Module</li><li><i>11</i> - Optical module for the FNN meters</li><li><i>12</i> - smart-me 3-Phase Meter 80A with the new WiFi (V2)</li><li><i>14</i> - smart-me 3-Phase Meter 80A with Mobile</li><li><i>16</i> - smart-me 1-Phase Meter 80A with the new WiFi (V2)</li><li><i>17</i> - smart-me 1-Phase Meter 32A with the new WiFi (V2)</li><li><i>18</i> - smart-me 1-Phase Meter 80A with GPRS</li><li><i>19</i> - smart-me 1-Phase Meter 32A with GPRS</li><li><i>21</i> - smart-me 3-Phase Meter Transformer Edition with mobile module</li><li><i>65</i> - smart-me 3-phase Meter Nimbus (3-point meter)</li><li><i>70</i> - Mithral hall charging station Version 1</li><li><i>1001</i> - REST API Meter</li><li><i>1002</i> - Virtual billing Meter (e.g. for smart-me washroom)</li><li><i>1003</i> - M-BUS Meter read out by a smart-me M-BUS Gateway</li></ul>
The Actvie Power or current flow rate
The Actvie Power Phase L1
The Actvie Power Phase L2
The Actvie Power Phase L3
The Unit of the Active Power Value
The Meter Counter Reading (Total Energy used)
The Unit of the Counter Reading
The Meter Counter Reading Tariff 1
The Meter Counter Reading Tariff 2
The Meter Counter Reading Tariff 3
The Meter Counter Reading Tariff 4
The Meter Counter Reading only import
The Meter Counter Reading only export
Flag if the Switch is on on this device.
Flag if the Phase L1 is on on this device.
Flag if the Phase L2 is on on this device.
Flag if the Phase L3 is on on this device.
The Voltage (in V)
The Voltage Phase L1 (in V)
The Voltage Phase L2 (in V)
The Voltage Phase L3 (in V)
The Current (in A)
The Current Phase L1 (in A)
The Current Phase L2 (in A)
The Current Phase L3 (in A)
The Power Factor (cos phi). Range: 0 - 1
The Power Factor (cos phi) Phase L1. Range: 0 - 1
The Power Factor (cos phi) Phase L2. Range: 0 - 1
The Power Factor (cos phi) Phase L3. Range: 0 - 1
The Temperature (in degree celsius)
The Number of the Active Tariff
The digital output number 1
The digital output number 2
The analog output number 1 (PWM signal) (0 - 32183)
The analog output number 2 (PWM signal) (0 - 32183)
The digital input number 1
The digital input number 2
Time of last successful connection the the smart-me Cloud.
An additional Meter serial number. e.g. the number of a meter a smart-me device is connected to.
The current flow rate (e.g. m3/h)
State of a (pico) charging station<p>Members: </p><ul><li><i>0</i> - Booting</li><li><i>1</i> - ReadyNoCarConnected</li><li><i>2</i> - ReadyCarConnected</li><li><i>3</i> - StartedWaitForCar</li><li><i>4</i> - Charging</li><li><i>5</i> - Installation</li><li><i>6</i> - Authorize</li><li><i>7</i> - Offline</li></ul>
Changes
No recorded changes to this operation across all 1 revision of this API.