Physical flow

Get measured physical flow

Get measured physical electricity flows (ENTSO-E TR 12.1.G).

Returns measured physical flow — not commercial or nominated schedules (TR 12.1.F). Covers both cross-border and inter-zonal pairs (e.g. IT-NO↔IT-CNO, IT-CAL↔IT-SIC). URL keeps the legacy exchange slug for backwards compatibility.

key can be either a zone key or a flow pair key:

  • Zone key (e.g. DE): returns all pairs involving that zone (DE->FR, DE->NL, DE->AT, …).
  • Flow pair key (e.g. DE->FR): returns data for that single pair only. Use GET /v1/exchanges to list all valid pair keys.

Response fields:

  • net_flow: Physical flow in MW. For zone queries, oriented to the queried zone — positive means the queried zone is exporting. For pair queries, oriented to the zone_from in the pair key — positive means flow from zone_from to zone_to.
get/v1/exchange/flows/{key}

Request

  • Base URL: https://grid.rebase.energy/api
  • URL: https://grid.rebase.energy/api/v1/exchange/flows/{key}
  • Auth: one of:
    • API key in query parameter api_key
    • API key in header X-API-Key

Path parameters

keystring required

Query parameters

sourcestring nullable

Data source for physical flows.

resolution'native' | '5M' | '15M' | '30M' | '1H'

Output cadence the caller asked for on a series endpoint.

NATIVE means: leave the series at its upstream cadence and leave holes as null where data is missing. The other members snap the series onto a uniform grid: 5M, 15M, 30M, 1H.

Output cadence. native (default) emits each pair at its upstream cadence. 5M/15M/30M/1H resample onto the uniform grid: mean-downsample if coarser, ffill-upsample (one upstream interval) if finer.

startstring date-time nullable

Start of time range (ISO 8601). Default: 24h ago.

endstring date-time nullable

End of time range (ISO 8601). Default: now.

Response

Successful Response

zone_keystring required

Queried zone

sourcestring required

Data source used for this response

data_typestring
resolutionstring

Output cadence. native returns the upstream cadence. 5M/15M/30M/1H resample onto a uniform grid (mean-downsample if coarser, ffill-upsample carrying one upstream interval if finer).

startstring required

Start of time range (ISO 8601)

endstring required

End of time range (ISO 8601)

Changes