thermostats

GET /v4/thermostats/{deviceId}/configuration

Changed on

Request

  • Base URL
    https://api.honeywellhome.com
  • Auth
    • OAuth 2
      Client credentials
      Token URLhttps://login.resideo.com/oauth/token
      Scopesopenid profile email
    • or API key in header Authorization

Path parameters

deviceIdstring required

Response

OK

DeviceIdstring nullable
SystemSwitchCapabilitiesSystemSwitchCapabilityEnumResponse[] nullable
DehumidifierEnabledboolean nullable
DehumidificationMaximumSetpointinteger nullable
DehumidificationMinimumSetpointinteger nullable
HumidifierDeadbandEnabledboolean nullable
HumidifierDeadbandinteger nullable
HumidifierEnabledboolean nullable
HumidificationMaximumSetpointinteger nullable
HumidificationMinimumSetpointinteger nullable
MinimumCoolSetpointAllowednumber double nullable
MaximumCoolSetpointAllowednumber double nullable
MinimumHeatSetpointAllowednumber double nullable
MaximumHeatSetpointAllowednumber double nullable
SetpointDeadbandnumber double nullable
CommercialConfigurationboolean nullable

True = commercial configuration, false = residential configuration. If not present, then commerical configuration.

MaximumOverrideDurationAllowedinteger nullable

Must be present if cmml = true and must not be present if cmml = false. The maximum override duration allowed in hours. Note if the thermostat has been configured to have no limit, the maximum override duration is 24 hours and must be encoded as such.

BackLightIntensityinteger nullable
MaximumBackLightIntensityinteger nullable
MinimumBackLightIntensityinteger nullable
AllowedAdaptiveRecoveryModesAdaptiveRecoveryModeEnumResponse[] nullable
TemperatureUnits'Unknown' | 'F' | 'C'
SupportedCapabilitiesSupportedCapabilityEnumResponse[] nullable
AllowedTimeIncrementsinteger nullable
DeviceNamestring nullable
MaximumAllowedRoomsPerGroupinteger nullable
MaximumGroupsPerGroupOfGroupsAllowedinteger nullable
MaximumAllowedRoomsinteger nullable
MaximumAccessoriesPerRoominteger nullable
MaximumAllowedGroupsinteger nullable
ContractorPortalNumberstring nullable
TemperatureUnitsWritableboolean nullable
AirFilterRemindersobject nullable
AwayModeOverrideboolean nullable

True = detection of occupancy will automatically bring the thermostat out of away mode. False = detection of occupancy will not automatically bring the thermostat out of away mode.

VentilationModeCapabilityVentilationModeCapabilityEnumResponse[] nullable

Changes

    • breaking

      removed the media type text/json for the response with the status

    • breaking

      removed the media type text/plain for the response with the status

    • info

      api operation id getThermostatsDeviceIdConfiguration was added