Site Level Consumption Monitoring

Returns a system's last reported PV Power, Consumption Power, Battery Power and EVSE Power in Watts. Return’s operational mode for Battery, HP, and EVSE

Returns a system's last reported PV Power, Consumption Power, Storage meter Power, Battery Power and EVSE Power in Watts. Return's operational mode for Battery, HP, and EVSE. If the last_report_at is older than 7 days for a specific device, "last_report_at", "power" and "operational_mode" parameters will be returned in the response with the value as null.

PV + Storage sites will always be configured in Net Config. PV only sites can configured either as Net or Total config.

For PV only sites configured as Net config (load with solar), consumption power is calculated as: production + grid.

For PV only sites configured as Total config, consumption power provided as raw value measured by consumption CT (e.g. the home load).

For PV + Storage sites in Net config, consumption power is calculated as production + grid. It does not include battery.

Consumption - battery = home load (e.g. fixed load)

battery is not considered fixed load, but can contribute to supplying the fixed load.

The consumption meter config is available in the /api/v4/system/{system_id}/devices endpoint. Refer to 'config_type' parameter.

HP Modes:

Mode_1 - Blocked Operation Mode_2 - Normal Operation Mode_3 - Power Consumption Recommended Mode_4 - Power Consumption Enforced

EVSE Modes:

PLUGGED_OUT - EV Charger is not plugged in IDLE - EV Charger is plugged in but, EV is not charging CHARGING - EV Charger is plugged in and EV is charging FAULTED - The EV Charger connector is faulted SUSPENDED_EV - The charging session was suspended by the EV SUSPENDED_EVSE - The charging session was suspended by the EV charger UNAVAILABLE - EV charger is plugged in, but not authorized

get/api/v4/systems/{system_id}/latest_telemetry

Request

Path parameters

system_idinteger required

The unique numeric ID of the system

Response

List of devices

system_idinteger

System id

itemsstring

The list key 'devices'

devicesobject

Hash keys include meters, Encharges, heat pumps and EVSEs

Changes

No recorded changes to this operation across all 2 revisions of this API.