---
title: "Get link station details"
method: GET
path: "/v1/link-stations/{id}"
tags: ["Link station information & management"]
---

# Get link station details

`GET /v1/link-stations/{id}`

## Request

- Base URL: `https://api.ui.com/v1/connector/consoles/942A6FF664C0000000000964970E0000000009E710560000000068A9873F:9999999999/proxy/protect/integration`
- URL: `https://api.ui.com/v1/connector/consoles/942A6FF664C0000000000964970E0000000009E710560000000068A9873F:9999999999/proxy/protect/integration/v1/link-stations/{id}`
- Auth: none declared
- TypeScript: <https://skmtc.dev/ubiquiti/apis/unifi-protect-api/docs/v1/link-stations/:id/get.ts> (a function with typed inputs; its response is checked against the schema)

Get detailed information about a specific link station (non-alarm hub gateways)

## Path parameters

- `id` string, required: The primary key of linkStation

## Response `200`

Success response

- LinkStation
  - `id` string, required: The primary key of linkStation
  - `modelKey` 'linkstation', required: The model key of the linkstation
  - `state` 'CONNECTED' | 'CONNECTING' | 'DISCONNECTED', required: Connection state of the device.
  - `name` string, required: The name of the device.
  - `mac` string, required: The primary MAC address of the device.
  - `isAlarmHub` boolean, required: Whether the linkstation is an alarm hub.
  - `ledSettings` LinkStationLedSettings, required: Status LED settings.
    - `isEnabled` boolean, required: Whether the status LED is enabled.
  - `lastEvent` number, nullable, required: Timestamp when any last event was detected.
  - `alarmHub` AlarmHubStatus: Alarm hub status and configuration. Only present when isAlarmHub is true.
    - `armed` 'on' | 'off', required
    - `battery` object
      - `charging` 'on' | 'off'
      - `connection` 'connected' | 'disconnected'
      - `voltage` number
      - `batteryStatus` 'ok' | 'low' | 'critical'
    - `buckboost` 'on' | 'off', required
    - `connector` object
      - `emergency` object
        - `+` 'connected' | 'disconnected', required
        - `-` 'connected' | 'disconnected', required
      - `12v` object
      - `relay` object
      - `tb` object
      - `battery` 'connected' | 'disconnected'
      - `poeout` 'connected' | 'disconnected'
    - `cover` object
      - `distance` integer
      - `status` 'open' | 'close'
    - `currentMeterChannelStatus` object, required
    - `currentMeterStatus` object, required
    - `inputPower` object
      - `bt` 'low' | 'high'
      - `typ1` 'low' | 'high'
      - `typ2` 'low' | 'high'
    - `poeout` object
      - `connection` 'connected' | 'disconnected'
      - `powerSupply` 'on' | 'off'
    - `powerMeter` object, required
    - `output` object, required
    - `input` object, required
    - `inputTerminalStatus` object
    - `outputTerminalStatus` object
    - `emergencyTerminalStatus` object, nullable
      - `plusPinStatus` 'disabled' | 'idle' | 'not-connected' | 'tamper' | 'triggered' | 'cut' | 'short', required
      - `minusPinStatus` 'disabled' | 'idle' | 'not-connected' | 'tamper' | 'triggered' | 'cut' | 'short', required
      - `terminalStatus` 'disabled' | 'idle' | 'not-connected' | 'tamper' | 'triggered' | 'cut' | 'short' | 'partially-connected', required
      - `idleSubState` 'open' | 'closed'
    - `auxiliaryPowerTerminalStatus` object

## Other responses

- `default`: Error response

---

[API](https://skmtc.dev/ubiquiti/apis/unifi-protect-api.md) - [All operations](https://skmtc.dev/ubiquiti/apis/unifi-protect-api/llms.txt) - [OpenAPI document](https://skmtc.dev/ubiquiti/apis/unifi-protect-api/revisions/e341e1381db1?raw)
