title: "Update retrofit retire plan"
method: POST
path: "/refrigeranttracking/UpdateRetrofitRetirePlan"
tags: ["RefrigerantTracking"]
---

# Update retrofit retire plan

`POST /refrigeranttracking/UpdateRetrofitRetirePlan`

## Request

- Base URL: `https://sb2api.servicechannel.com/v3`
- URL: `https://sb2api.servicechannel.com/v3/refrigeranttracking/UpdateRetrofitRetirePlan`
- Auth: OAuth 2
  - Authorization code: `https://sb2login.servicechannel.com/oauth/authorize`
  - Token URL: `https://sb2login.servicechannel.com/oauth/token`
- TypeScript: <https://skmtc.dev/servicechannel/apis/servicechannel-api-v-3/docs/refrigeranttracking/UpdateRetrofitRetirePlan/post.ts> (a function with typed inputs; its response is checked against the schema)

## Request body

- ServiceChannelServicesWebApiModelsRequestRefrigerantTrackingUpdateRetrofitRetirePlanWebRequest
  - `RetrofitRetirePlanData` ServiceChannelServicesWebApiModelsRequestRefrigerantTrackingUpdatePlanGeneralDataWeb
    - `PlanId` integer: Unique identifier of the plan to update
    - `StartDate` string, date-time: Updated start date of the plan
    - `EndDate` string, date-time: Updated end date of the plan
    - `Description` string: Updated description of the plan
    - `ProviderName` string: Updated provider/vendor name
    - `DifferentRefrigerantQtyReason` string
    - `NewChargeDetermination` string
  - `RefrigerantRemovalData` ServiceChannelServicesWebApiModelsRequestRefrigerantTrackingUpdateRefrigerantRemovalDataWeb
    - `PartId` integer: Part usage record ID to update
    - `Date` string, date-time: Updated date when refrigerant was removed
    - `Qty` number, double: Updated quantity of refrigerant removed
    - `RefrigerantRemovalStatus` string: Updated refrigerant removal status (e.g., Disposed, Reused)
  - `RefrigerantEnteredData` ServiceChannelServicesWebApiModelsRequestRefrigerantTrackingUpdateRefrigerantEnteredDataWeb
    - `PartId` integer: Part usage record ID to update
    - `Date` string, date-time: Updated date when refrigerant was entered/added
    - `Qty` number, double: Updated quantity of refrigerant entered/added

## Response `200`

The request succeeded and the requested information is in the response.

- SystemObject

## Other responses

- `400`: The request was not accepted due to bad syntax, missing parameters, insufficient data, etc.
- `500`: Something went wrong, and the server was unable to complete your request. <br>Error codes: 501 - Internal Error
- `503`: The request was not accepted because the user is not a Refrigerant Tracking Admin.

---

[API](https://skmtc.dev/servicechannel/apis/servicechannel-api-v-3.md) - [All operations](https://skmtc.dev/servicechannel/apis/servicechannel-api-v-3/llms.txt) - [OpenAPI document](https://skmtc.dev/servicechannel/apis/servicechannel-api-v-3/revisions/d490d6596809?raw)