---
title: "Echo picklist export"
method: POST
path: "/export_echo_picklist"
tags: ["Files & formats"]
---

# Echo picklist export

`POST /export_echo_picklist`

## Request

- Base URL: `https://seqbench.com/api/v1`
- URL: `https://seqbench.com/api/v1/export_echo_picklist`
- Auth: none required

Generate a downloadable Beckman/Labcyte Echo acoustic-liquid-handler picklist CSV (columns: Source Plate Name, Source Plate Type, Source Well, Destination Plate Name, Destination Well, Transfer Volume, Name — the header row reproduced from PyEcho, a real open-source Echo-picklist generator) for the given PCR reactions, at the same well positions export_plate_layout assigns. Assumes a 5 uL Echo-scale PCR reaction (master mix 2500 nL, each primer 250 nL, template 250 nL, water 1750 nL) — a commonly used acoustic-dispensing miniaturization scale, not a universal standard; rescale the volumes for your own protocol. Source/Destination Plate Type uses a placeholder Echo plate-type code (384PP_AQ_BP) — replace with the exact type from your own Echo Plate Type Library. Each distinct template label gets its own well on the TemplateSource plate, row-major (A1, A2, … A24, then B1, …) across that 384-well source plate.

## Request body

- object
  - `reactions` object[], required: One entry per PCR reaction, up to 96 (a single 96-well plate).
    - `name` string: Reaction/construct name.
    - `forward` string, required: Forward primer sequence, 5'->3' (IUPAC accepted).
    - `reverse` string, required: Reverse primer sequence, 5'->3' (IUPAC accepted).
    - `template` string: Optional template name/id — a short label (e.g. a plasmid or sample name), not a sequence.

## Response `200`

Tool ran successfully.

- SuccessResponse: Standard success envelope returned by every single-tool call.
  - `ok` unknown, required
  - `tool` string, required: The tool slug that ran.
  - `result` object, required: Tool-specific output object. Its shape depends on the tool — call `GET /{tool}` or see the docs for each tool's fields.
  - `gate` GateResult
    - `pass` boolean, required: True if and only if every hard check passed.
    - `checks` GateCheck[], required
      - `id` string, required
      - `label` string, required
      - `severity` 'hard' | 'soft', required
      - `pass` boolean, required
      - `message` string, required
      - `value` number
      - `threshold` string
    - `notChecked` string[], required: Honest list of what this gate does NOT verify.
  - `provenance` Provenance, required
    - `apiVersion` string, required
    - `tool` union, required: Tool slug, or an array of slugs (one per step) for a workflow.
      - string
      - string[]
    - `generatedAt` string, date-time, required: ISO 8601 timestamp of when the result was generated.

## Other responses

- `400`: Invalid argument or the tool could not run.
- `404`: Unknown tool.
- `429`: Rate limited (metered tools only). Body carries code `rate_limited` and retryable `true`; honor the Retry-After header.
- `503`: A metered tool is momentarily at capacity. The identical request should succeed after Retry-After; body carries code `upstream_unavailable`.

---

[API](https://skmtc.dev/seqbench/apis/seqbench-api.md) · [All operations](https://skmtc.dev/seqbench/apis/seqbench-api/llms.txt) · [OpenAPI document](https://skmtc.dev/seqbench/apis/seqbench-api/revisions/132575216865?raw)
