title: "GET /monitors/{id}"
method: GET
path: "/monitors/{id}"
tags: ["Monitors"]
---

# GET /monitors/{id}

`GET /monitors/{id}`

## Request

- Base URL: `https://api.axiom.co/v2`
- URL: `https://api.axiom.co/v2/monitors/{id}`
- Auth: OAuth 2
  - Authorization code: `https://accounts.google.com/o/oauth2/v2/auth`
  - Token URL: `https://www.googleapis.com/oauth2/v4/token` scopes: `monitors|read`
- TypeScript: <https://skmtc.dev/axiom/apis/axiom-public-api/docs/monitors/:id/get.ts> (a function with typed inputs; its response is checked against the schema)

Retrieves a monitor by ID. Returns `404` if the monitor doesn't exist or the caller can't query its datasets. Labels are resolved unless `exclude=labels`.

## Path parameters

- `id` string, required

## Query parameters

- `exclude` 'labels'

## Response `200`

Monitor.

- MonitorWithId: Configuration for a monitoring rule. Monitors can be configured to: - Check threshold values (e.g., CPU usage > 90%) - Match specific events in logs - Detect anomalies based on historical patterns Each monitor runs on a specified interval and can trigger notifications through configured notifiers.
  - `alertOnNoData` boolean: Whether to alert when no data is received
  - `aplQuery` string: APL (Axiom Processing Language) query string used for monitoring. This query defines what data to analyze and how to process it. At least one of aplQuery or mplQuery must be provided.
  - `columnName` string: Name of the column to monitor
  - `compareDays` number: Number of days to compare for anomaly detection
  - `description` string: Detailed description of the monitor's purpose
  - `disabled` boolean: Whether the monitor is currently disabled
  - `disabledUntil` string, date-time, nullable: Timestamp until when the monitor should remain disabled
  - `includeChart` boolean: Whether to include a query chart in triggered notifications
  - `intervalMinutes` integer: How frequently the monitor should run, in minutes. Minimum value is 1 minute.
  - `mplQuery` string: MPL (Metrics Processing Language) query string for metrics-based monitoring. Use this as an alternative to aplQuery for metrics datasets. At least one of aplQuery or mplQuery must be provided.
  - `name` string, required: Name of the monitor
  - `notifierIds` string[]: List of notifier IDs that will receive alerts. Notifiers can be email, Slack, webhook endpoints, etc.
  - `notifyByGroup` boolean: Whether to group notifications
  - `notifyEveryRun` boolean: Whether to send notifications on every check
  - `operator` 'Below' | 'BelowOrEqual' | 'Above' | 'AboveOrEqual' | 'AboveOrBelow': Comparison operator for threshold checks: - Below: Trigger when value < threshold - BelowOrEqual: Trigger when value <= threshold - Above: Trigger when value > threshold - AboveOrEqual: Trigger when value >= threshold - AboveOrBelow: Trigger when value is outside a range
  - `rangeMinutes` integer: Time window to evaluate in each check, in minutes. For example, "last 5 minutes of data"
  - `resolvable` boolean: Whether the alert can be manually resolved
  - `secondDelay` number: Number of seconds to move each run's query window into the past, so data that arrives late is included. For example, with a value of 300, a run at 10:05 queries up to 10:00.
  - `skipResolved` boolean: Whether to skip resolved alerts
  - `threshold` number, double: Threshold value for triggering the alert
  - `tolerance` number: Tolerance percentage for anomaly detection
  - `triggerAfterNPositiveResults` number: Number of runs among the last `triggerFromNRuns` runs, including the current one, that must meet the trigger condition for the monitor to trigger. The current run must always meet it. For example, set both fields to 3 to trigger only after 3 consecutive runs meet the condition. If unset or 0, the first run that meets the condition triggers. Values above `triggerFromNRuns` are lowered to it when the monitor is saved. Applies to Threshold and AnomalyDetection monitors.
  - `triggerFromNRuns` number: Number of most recent runs, including the current one, that the monitor looks at when deciding whether to trigger. Has no effect unless `triggerAfterNPositiveResults` is also set. Applies to Threshold and AnomalyDetection monitors.
  - `type` 'Threshold' | 'MatchEvent' | 'AnomalyDetection', required: Type of monitoring check to perform: - Threshold: Compares a numeric value against a threshold - MatchEvent: Looks for specific events or patterns - AnomalyDetection: Identifies unusual patterns based on historical data
  - `createdAt` string, date-time: Timestamp when the monitor was created
  - `createdBy` string: ID of the user who created the monitor
  - `createdByAgent` boolean: true when the MCP server created this monitor
  - `datasets` string[]: Dataset names referenced by the monitor query.
  - `id` string, required: Unique identifier for the monitor
  - `labelIds` LabelID[], required: IDs of labels assigned to this monitor.
  - `labelNames` string[], required: Names of assigned labels, including with exclude=labels; [] when unassigned.
  - `labels` Label[]: Resolved labels assigned to this monitor.
    - `color` LabelColor, required
      - `name` 'red' | 'coral' | 'orange' | 'amber' | 'yellow' | 'lime' | 'green' | 'teal' | 'blue' | 'iris' | 'purple' | 'pink', required
      - `type` 'palette', required
    - `description` string, nullable
    - `id` string, required
    - `name` string, required
  - `lastError` string: Most recent error encountered while evaluating the monitor.
  - `updatedAt` string, date-time: Timestamp when the monitor was last updated

## Other responses

- `404`: Not found

## Changes

- **2026-11-04** (v2) `ce3b16fc7723`: 1 warning, 1 info
  - removed the optional property `allOf[#/components/schemas/Monitor]/lookbackDays` from the response with the `200` status
  - removed the `NewValues` enum value from the `allOf[#/components/schemas/Monitor]/type` response property for the response status `200`
- **2026-11-02** (v2) `e3baf3b85e8d`: 1 warning, 4 info
  - added the new `NewValues` enum value to the `allOf[#/components/schemas/Monitor]/type` response property for the response status `200`
  - added the optional property `allOf[#/components/schemas/Monitor]/includeChart` to the response with the `200` status
  - added the optional property `allOf[#/components/schemas/Monitor]/lookbackDays` to the response with the `200` status
  - added the optional property `allOf[subschema #2]/createdByAgent` to the response with the `200` status
  - …1 more
- **2026-10-16** (v2) `fbc1b8430feb`: 1 info
  - added the non-success response with the status `404`
- **2026-10-14** (v2) `8920e1697284`: 3 warning, 8 info
  - removed the optional property `allOf[#/components/schemas/Monitor]/createdAt` from the response with the `200` status
  - removed the optional property `allOf[#/components/schemas/Monitor]/createdBy` from the response with the `200` status
  - removed the optional property `allOf[#/components/schemas/Monitor]/updatedAt` from the response with the `200` status
  - added the new optional `query` request parameter `exclude`
  - …7 more

[Operation history](https://skmtc.dev/axiom/apis/axiom-public-api/changes/monitors/:id/get.md)

---

[API](https://skmtc.dev/axiom/apis/axiom-public-api.md) - [All operations](https://skmtc.dev/axiom/apis/axiom-public-api/llms.txt) - [OpenAPI document](https://skmtc.dev/axiom/apis/axiom-public-api/revisions/7e39a295e3ba?raw)