title: "Get project technical feasibility"
method: GET
path: "/projects/{projectId}/technical-feasibility"
tags: ["Projects"]
---

# Get project technical feasibility

`GET /projects/{projectId}/technical-feasibility`

## Request

- Base URL: `https://api3.autarc.energy/v1`
- URL: `https://api3.autarc.energy/v1/projects/{projectId}/technical-feasibility`
- Auth: API key in header `X-Api-Key`

Returns the technical feasibility data recorded for a project.

## Path parameters

- `projectId` string, required

## Response `200`

OK

- TechnicalFeasibility: Technical feasibility data recorded for a project.
  - `buildingType` string, nullable, required
  - `buildingAge` string, nullable, required
  - `numberOfResidents` number, nullable, required
  - `numberOfFloors` number, nullable, required
  - `heatedLivingAreaM2` number, nullable, required
  - `isMonumentProtected` boolean, nullable, required
  - `windowGlazingType` string, nullable, required
  - `isFacadeInsulated` boolean, nullable, required
  - `isRoofInsulated` boolean, nullable, required
  - `nameEnergyHeating` string, nullable, required
  - `nameSupplierElectricity` string, nullable, required
  - `currentElectricPrice` number, nullable, required
  - `currentGasPrice` number, nullable, required
  - `buildingNotes` string, nullable, required
  - `installationDate` string, date-time, nullable, required
  - `oldHeatingSystemType` string, nullable, required
  - `oldHeatingSystemConstructionYear` string, nullable, required
  - `drinkingWaterHeatingSystemType` string, nullable, required
  - `hotWaterConsumptionPerPersonPerDay` number, nullable, required
  - `roomHeatingType` string, nullable, required
  - `pipeSystemType` string, nullable, required
  - `maxFlowTemperature` number, nullable, required
  - `lastHydraulicBalancingYear` number, nullable, required
  - `averageEnergyConsumptionLast3Years` number, nullable, required
  - `materialFlowReturnHeating` string, nullable, required
  - `materialHotWaterConnection` string, nullable, required
  - `numberRadiators` number, nullable, required
  - `radiatorHotWarm` string, nullable, required
  - `numberOfRainShowers` number, nullable, required
  - `numberOfBaths` number, nullable, required
  - `numberOfShowers` number, nullable, required
  - `numberOfWhirlpools` number, nullable, required
  - `hasUnderfloorHeating` boolean, nullable, required
  - `hasRainShowerBath` boolean, nullable, required
  - `oilTankDisposal` string, nullable, required
  - `typeOilTank` string, nullable, required
  - `sizeOilTank` number, nullable, required
  - `materialOilTank` string, nullable, required
  - `hasSolarThermalSystem` boolean, required
  - `solarThermalSystemType` string, nullable, required
  - `solarThermalCollectorArea` number, nullable, required
  - `ageOfSolarThermalSystem` number, nullable, required
  - `hasFireplace` boolean, required
  - `fireplaceWoodType` string, nullable, required
  - `fireplaceBurntWoodSt` number, nullable, required
  - `heatingSystemNotes` string, nullable, required
  - `narrowestPassage` number, nullable, required
  - `deepestPassage` number, nullable, required
  - `heatingRoomNotes` string, nullable, required
  - `passageNotes` string, nullable, required
  - `alternativeHeatingRoom` string, nullable, required
  - `distanceOutdoorUnitHeatingRoom` number, nullable, required
  - `bedroomBoundaries` boolean, nullable, required
  - `levelDifference` number, nullable, required
  - `undergroundBreakthrough` string, nullable, required
  - `outerWallMaterial` string, nullable, required
  - `undergroundPipes` boolean, nullable, required
  - `hasAdjacentBuilding` boolean, nullable, required
  - `distanceToBuilding` number, nullable, required
  - `heatpumpNotes` string, nullable, required
  - `heatpumpLocationLat` number, nullable, required
  - `heatpumpLocationLng` number, nullable, required
  - `hasPvSystem` boolean, nullable, required
  - `pvSystemNumberOfModules` number, nullable, required
  - `pvSystemKwp` number, nullable, required
  - `pvSystemConstructionCompany` string, nullable, required
  - `pvSystemHasStorage` boolean, nullable, required
  - `pvSystemStorageCapacityKwh` number, nullable, required
  - `pvSystemAnnualYieldKwh` number, nullable, required
  - `distanceFromMeterClosetToIndoorUnitHP` number, nullable, required
  - `meterClosetManufacturer` string, nullable, required
  - `earthingRailPresent` boolean, nullable, required
  - `meterClosetAdjustment` string, nullable, required
  - `meterClosetLocation` string, nullable, required
  - `distanceBetweenMeterClosetAndHouseJunctionBox` number, nullable, required
  - `electricNotes` string, nullable, required
  - `technicalFeasibilityCheckAuditorId` string, nullable, required
  - `technicalFeasibilityAssesment` 'feasible' | 'notFeasible' | 'notStarted', required
  - `technicalFeasibilityCheckCompleted` boolean, nullable, required

## Other responses

- `404`: The specified resource was not found

---

[API](https://skmtc.dev/autarc/apis/autarc-2-0-api.md) - [All operations](https://skmtc.dev/autarc/apis/autarc-2-0-api/llms.txt) - [OpenAPI document](https://skmtc.dev/autarc/apis/autarc-2-0-api/revisions/adfb20a40efc?raw)